Conventional Control Panels ECO Series
  • Conventional fre alarm control panel for 2 zones and 4 zones
  • Up to 32 detectors per zone
  • 2 configurable supervised sounder outputs (500 mA each output), Alarm and fault relay outputs free of voltage, Auxiliary 24V output (500 mA maximum consumption), 24V resettable output (500 mA maximum consumption)
  • Sounder output delay configurable on board
  • Multilingual keyboard
  • Dimensions: 282 x 240 x 102 mm
  • ABS plastic housing
  • CPR certifcate EN54-2/4
Conventional fire alarm control panel
for 2 zones and 4 zones
Conventional Control Panels CCD-100 Series
  • Conventional fre alarm control panel for 2, 4, 8, 12 zones
  • Up to 32 detectors per zone
  • Possibility to connect to PC via USB for complex programming
  • Integrable to addressable systems directly to the loop
  • 2 configurable supervised sounder outputs (500 mA each output), alarm and fault relay outputs free of voltage, auxiliary 24V output (500 mA maximum consumption), 24V resettable output (500 mA maximum consumption) and 1 programmable external input
  • Option: TRD-100 Expansion card of 4 free voltage relay outputs, TSD-100 4 supervised sounder outputs, TMD-100 Modbus output for integrations, TPLD-100 Integration to addressable loop
  • Multilingual keyboard
  • Tele maintenance and remote control through TED-151-CL TCP / IP communication card (Detnov Cloud)
  • Dimensions: 443 x 268 x 109 mm
  • ABS plastic housing
  • CPR certifcate EN54-2/4/13
Conventional fre alarm control panel
for 2, 4, 8, 12 zones
Conventional Detectors
  • Elegant design and low profile
  • Dirtiness compensation
  • Dirtiness and insect protection
  • Led status indicator and output for remote pilot indicator
  • Two-wire connection without polarity
  • Colour: white and black
  • CPR certifcates EN 54-5/7
Optical smoke detector, Heat detector (58°C/8°C min.), High heat detector (78°C), Smoke and heat detector (MultiSensor)
Conventional Manual Call Point
  • Test key for maintenance test
  • Indoor and outdoor installation
  • Red, Green color
  • Includes 100Ω 2W resistance for the alarm level
  • CPR certificate EN54-11
Manual Call Point indoor and IP67 outdoor installation, Green color for evacuation and emergencies
Conventional Sounder, Beacon, Bell
  • Sounder: Multiple selectable tones, 24VDC, indoor and oudoor
  • Beacon: 24VDC, red, blue, amber, color glass, ceiling and wall installation, indoor and outdoor
  • Combined Sounder and Beacon
  • Bell: 24VDC, 94/101dB, indoor and outdoor
  • Light indicator with buzzer and beacon: 24VDC, 91dB, High brightness LED lighting, Polycarbonate case
  • CPR certificate EN54
Beacon, Sounder, Light Indicator, Bell